Sincro Systems Produse Module monitorizare IP Ethernet Poseidon Poseidon 4002 - Modul monitorizare mediu montabil in rack
Poseidon 3468 - Termostat IP, monitorizare si reglare IPPoseidon2 3266 - Monitorizare de la distanta a senzorilor LAN

Poseidon 4002 - Modul monitorizare mediu montabil in rack

Poseidon 4002 - Modul monitorizare mediu montabil in rack
Imagine mare


Poseidon 4002 is a 19" 1U rack mount system for datacenter temperature and environment monitoring. The Poseidon solution monitors racks and computer rooms (temperature, humidity, electricity supply, access to the room, detectors). Alerting works by e-mail, SNMP traps, SMS, output relays.

Poseidon 4002 is a complete system for environment monitoring in a rack or in a datacenter. The 4002 model can be mounted as a 1U device, or outside of the 42U space.

The Poseidon solution monitors a 19" rack or an entire server room. 18 sensors are supported (temperature, humidity, smoke, flood, electricity supply status or failure, entry to the room, digital inputs).

The Poseidon 4002 monitoring system fits into a 19" rack and is SNMP compatible. Two monitoring applications (PD Trigger and HWg-PDMS) are included free of charge.

Alerting to critical situations is performed by e-mail, SNMP Traps, SMS (GSM modem required) and output relays. The relays can be used, for example, to switch on a backup air-conditioning unit or to restart a server.

  • Built-in web server, SNMP compatible
  • Up to 18 sensors can be connected
    Humidity, smoke, temperature, flood, vibrations, entry to the room, air flow, water leak, input contacts, etc...

  • PD Trigger and HWg-PDMS monitoring software free of charge
Poseidon 4002: snmp environment monitoring

 

Poseidon 4002: rack mount environment monitoring
photo1   photo2
  photo3

 

online temperatureOnline demo

Poseidon XXXX (models overview)

 

Features

DOWNLOAD
  • Ethernet: RJ45 (10BASE-T)
  • WEB: Embedded WEB server / GUI
  • Sensors: 4xRJ11 1-Wire UNI (max 12 sensors)
    (Temperature, humidity, voltage, AC current, air flow, flood)
  • Inputs: 6 dry contact inputs (for detectors)
    (Smoke, power, water leak, door contact, air flow, entry to the room)
  • Outputs: 2 output relays (24 VDC)
    (Air conditioning, server power supply, horn / light tower)
  • M2M protocols: SNMP, XML and Modbus/TCP
  • Physical features: 10" or 19" rack mount, dimensions: 184 x 44 x 125 [mm] (1U)
     
  • Response to thresholds: SNMP trap, E-mail, SMS
  • Built-in functions: Output controlled with an input or sensor value ("Thermostat" mode).
  • Warranty: 5 years  
  • Support for programmers: HWg SDK
  • Supported software
    • HWg-PD Trigger: Controls other IP devices, redirects alarms to SMS
    • HWg-PDMS: Logging,export to MS Excel, reports
    • >> Third-party SNMP software
      (HP OpenView, IBM Tivoli, Nagios, Zabbix, Cacti, Monitor one, The Dude, Paessler IPCheck, Ipswitch WhatsUp, Axence nVision, CBR little:eye, LoriotPro, GFi NSM, SNMPc 7, CA NSM, ActiveXperts NM, Intellipool NM, MSC Operations Manager 2007)


>> Poseidon model XXXX - overview of models

 

Usage examples

rack mount environment monitoring

  • Data centers
    • Rack mount environment monitoring
    • Remote rack monitoring
    • Computer room temperature
    • SNMP environment monitoring system
  • Air-conditioning monitoring
    • A/C operation and water leak detection
    • Computer room temperature
    • Humidity in the datacenter (inside racks, in the A/C outlet, under the raised floor)
    • Rack mount temperature monitoring system
  • UPS / back-up generator monitoring
    Fuel level, diesel generator status, remote start over IP, monitoring of temperature and service contacts

  • Security systems

    • IP surveillance systems (external sensors)
    • Equipment status, access control systems

Poseidon 4002: rack mount temperature monitoring system

 

Sensors

Temperature, humidity, voltage, AC current, air flow, flood, electricity supply, water leak detector, door contact, air flow, entry to the room

1-Wire UNI sensors

  • Total bus length max 30 m
  • Each sensor has its own SafeRange. When the range is exceeded (alarm), e-mail or SNMP trap is invoked.

Dry contact inputs (for detectors):

Digital outputs (relays)

  • Electricity supply control: PowerEgg to detect and control 110/230V

>> More sensors

 

Which software to use

    HWg-PDMS: rack mount temperature monitoring system
  • Configuration: UDP Config  - IP address configuration
  • Event processing: PD Trigger - reacts to events
  • Monitoring and logging: HWg-PDMS - Monitoring software with MS Excel reporting
  • Visualization: CapTemp - Process monitoring and control
  • Other applications: Third-party SNMP software
     
  • For programmers: HWg-SDK contains interface descriptions and examples of using M2M protocols in several programming languages
    (JAVA, PHP, Borland C++ Builder 6.0, Microsoft Visual C++ 6.0, Borland Delphi 6.0, Microsoft Visual Basic & Excel VBA, VB.NET, C code for Linux, JavaScript (AJAX) Microsoft Visual C# 2005 (.NET))

 

PD Trigger application example

With the PD Trigger application for Windows, it is possible to receive alarms (SNMP traps) from an unlimited number of Poseidon products and define conditions and actions based on the originating device and the probe name. For example:

  • In case of air conditioning failure in server room A, send a SMS to Peter
  • In case of alarm in server room B, send e-mail to Tom
  • In case of electricity supply failure anywhere, send SMS to Peter and turn on a warning light at the receptionist's desk

Poseidon 4002: rack mount environment monitoring, e-mail alerting, sms alerts

>> Software for the Poseidon family

 

Ordering and FAQ

  • How can I plot the temperature in a graph?
    To monitor temperature, use the supplied HWg-PDMS software.
  • Where can I find the MIB file for connecting with my SNMP software?
    The "HWg-STE.mib" file is available at the main webpage of the product. Click to MIB, save it and import it into your SNMP software.
  • Is it possible to control an output using a sensor, e.g. switch on something if the temperature exceeds 35°C?
    Yes, the output can be controlled with a "local condition". We call this the "Thermostat" mode. You can configure this mode and set the threshold temperature (35°C) on the "Outputs" tab.
  • Can I use Poseidon without a SNTP server?
    Yes, of course. SNTP server is used to synchronize time and to initialize the clock after power up. However, the time shown in e-mails will be incorrect.
  • What is the maximum distance of sensors from the unit?
    Contact-based probes can be connected over tens of meters. RJ11 1-Wire sensors can be connected max. 30 meters away, if you use one sensor per one Poseidon connector. If you use a T-Box hub, the total maximum length is 10 m.
  • Where is the RS-485 bus?
    Poseidon model 4002 does not support RS-485, use Poseidon 2250.
  • How can I create a report with recorded temperatures?
    Use the supplied HWg-PDMS software. Values recorded in the database can be displayed or exported to MS Excel.
  • Can I send SMS alerts?
    Poseidon 4002 supports e-mail warnings and SMS alerts. To send SMS alerts, you need to connect a GSM modem with a SIM card inserted.
  • Where can I find the prices of your devices?
    Ask our distributors, or request a quote directly from us using the form at this page.
  • What is the lead time for ordered samples?
    We keep Poseidon units in stock, samples are shipped within 24 to 48 hours.
    When the order is confirmed, we inform you by e-mail about the approximate delivery date.
  • What is the warranty?
    The standard warranty is 2 years, can be extended upon request.

Order

Product Description
Poseidon 4002  Supplied without the power adapter, without sensors and without the 19" rack mount bracket.
Poseidon 4002 Tset Poseidon 4002, 19“ rack mount bracket, EU power adapter, Temp19 rack mount temperature sensor, temperature probe on a 3m cable.

 

Accessories

  • L profile 19" size: 19" rack mount bracket for Poseidon 4xxx [600 377]
  • GSM Modemcom G10: GSM modem for sending SMS alerts, supplied with an adapter [600 312]
  • Power adapter


Recomandati produsul / pagina:
 
Sincro Systems SRL
Str. Matei Basarab, nr. 85, bl. L119bis, ap. 2, sector 3, București, RomÃĒnia
Telefon: 021-320.66.02, 0723.369.867; Fax: 021-327.30.07
Email: office@sincro.ro