P8610 - Ethernet Thermometer with PoE

APPLICATIONS:

    • Server rooms monitoring
      Temperature monitoring of the server rooms and rack units, SNMP monitoring, alert by email and Syslog



    • Museums, archives, galleries
      Temperature is requested for rooms where old valuable documents are stored, history data to DBS Sensor monitor software, alert by email

    • Factories and manufacturing
      Temperature monitoring for food processing industry, pharmaceutical industry, aerospace industry, etc.

    • Home automation
      Residential room monitoring, history data to free software SensorReader, alert by email

  • Air-conditioned rooms
    Temperature rising indicates cooling fault, alert by email
T-internal Ethernet PoE WWW WWW config 1000 values Graph CSV Email Modbus XML SNMP Trap SOAP Syslog SNTP




P8541 demo

SOFTWARE:

    • DSB Sensor monitor
      Complex solution for data acquisition and analysing. Easy to use and high flexible database software for Comet Transmitters and Regulators. One licence of DBS Sensor monitor software allows collect data from unlimited number of devices.

    • T-Sensor software
      Free configuration utility for Comet Transmitters and Regulators.

    • SensorReader software
      Basic data acquisition utility for Comet Transmitters and Regulators. Software is free for download.

Online Ethernet Monitoring system

FEATURES:

Internal tempearture sensor
T-internal Device is designed for measuring temperature from internal sensor. Temperature can be displayed in degree of Celsius or degree of Fahrenheit.
Ethernet interface
Ethernet 10Base-T/100Base-TX Ethernet interface via standard RJ45 connector. IP address can be obtain automatically from DHCP server or set manually. Internet protocol version 4 is supported only.
Power over Ethernet
PoE Power over Ethernet according IEEE 802.3af standard. Cost and time to integration can be reduced using Power over Ethernet feature. Only Ethernet infrastructure with PoE switch is needed to get device to work.
WWW server
WWW WWW config Actual measured values are accessible via powerful embedded web server. Web pages are ready for access from mobile devices like smartphones and tablets. Device configuration via web pages is possible too. The device allows you to user customize the design of web pages.
History values memory
1000 values Measured values are stored into history memory according selected time interval. Capacity of the memory is 1000 records. Values inside history memory are not backuped. Memory is cleared after device restart.
History graphs
Graph Graphs with history values are accessible via web pages. Modern HTML5 canvas graphic component allows to use graphs from thousands of devices. It is not problem show graphs on tablets or smartphones. All modern web browsers are supported - Firefox, Opera, Chrome or Internet Explorer 9.
History export to CSV
CSV History values can be exported for next processing by the CSV file. CSV file can be processed inside spreadsheet application like Microsoft Excel or OpenOffice Calc. Two formats of CSV file are supported - dot and comma decimal point separators. Timestamps inside CSV file are shown when device time is synchronised by the SNTP server. CSV file can be downloaded from web pages or periodically send as email attachment.
Email
Email Warning email are sent when measured value exceed selected limits. Emails are also send when values returns back into safe range. SMTP authentication is supported, but SSL not. Emails with CSV file attachment can be sent at selected intervals.
ModbusTCP protocol
Modbus Modbus protocol for communication with SCADA systems or third party software. Device use Modbus TCP protocol version. Two Modbus clients can be connected to device at one moment.
Actual values via XML
XML XML protocol for actual measured values reading. This protocol is suitable for device integration into 3rd party SCADA systems.
SNMP protocol
SNMP SNMP version 1 protocol for IT infrastructure. Using SNMP protocol you can read actual measured values, alarm status and alarm parameters. Via SNMP protocol is also possible to get last 1000 measured values from history table. MIB tables with OID description are available.
SNMP Trap
Trap SNMP Trap for IT infrastructure. The device allows sending Traps to selected Trap receiver server. Traps are sent in case of alarm or at error states like unable to send email, unable to deliver SOAP message, etc.
SOAP protocol
SOAP The device allows to send currently measured values via SOAP v1.1 protocol. The device sends values in XML format to the web server. The advantage of this protocol is that communication is initialized by the device side. Due to it is not necessary use port forwarding.
Syslog protocol
Syslog Syslog protocol for IT infrastructure monitoring systems. The device allows sending text message to selected Syslog server. Messages are sent in case of alarm or at error states like unable to send email, unable to deliver SOAP message, etc.
SNTP protocol - time synchronization
SNTP Time synchronisation with SNTP server. Actual time is shown at web pages and is necessary for timestamps inside CSV files. Synchronisation interval can be set to one day or to one hour.

 

 Technical Data:

Technical parametersValue
Output Ethernet
Measured Value Temperature
Construction Type Ambient Air
Design Industrial
Temperature Measuring Range -20 to +60°
Relay Output No
Two-State Input No
Lcd Display No
Accuracy of temperature measurement ±0.8°C over -10°C, ±2°C below -10°C
Resolution 0.1°C
Measuring interval 2s
Supported units degrees Celsius, degrees Fahrenheit
Temperature operating range -20 to +60°C
IP protection IP30
LAN connection RJ-45 connector, 10Base-T or 100Base-TX
Communication protocols WWW, ModbusTCP, SNMPv1, SOAP, XML
Protocols for alarms E-mail, SNMP Trap, Syslog
Configuration T-Sensor, WWW configuration
Power Power over Ethernet according to IEEE 802.3af or 5Vdc
Power connector co-axial, diameter 5.5 x 2.1 mm
Dimensions 88.5 x 126 x 39.5 mm (W x H x D), stem length 53 mm
Weight approximately 145g
Warranty 2 years

 

 

Accesorii optionale:

AC/DC adapter 230Vac to 5Vdc/1.2A
code: A1825
alt
Sensor holder for mounting to rack 19"
code: MP046
alt
DBS Sensor Monitor - database program for data acquisition from Ethernet sensors P8xxx, Tx5xx, Hx5xx
code: DBS
alt
DBV Database Viewer for database programs DBL, DBM, DBS
code: DBV
alt

 

pdf2 Descarcati brosura
pdf2 Descarcati manualul de utilizare
pdf2 Descarcati declaratia de conformitate
Icon soft Descarcati Tsensor 3.0.4.0 - software de configurare
Icon soft Descarcati SensorReader 2.0.0.2 - software de achizitie
Icon soft Descarcati Database Sensor Monitor - software de achizitie de la senzorii Ethernet
Icon soft Descarcati Database Viewer
Icon soft Descarcati versiunea Firmware 4-5-5-03
Icon soft Firmware Changelog

 

 

 



Recomandati produsul / pagina:
 
Sincro Systems SRL
Str. Matei Basarab, nr. 85, bl. L119bis, ap. 2, sector 3, București, RomĆ¢nia
Telefon: 021-320.66.02, 0723.369.867; Fax: 021-327.30.07
Email: office@sincro.ro